| Info: Computational➢CPU-Time (s)Shows the computation time referring to the active simulation.
 ➢SimulatorShows whether the  fixed-grid or the adaptive grid simulator was used for simulating the active simulation.
 Info: Space Grid➢Grid Points (X)Shows the number of grid points used for simulating the concentration profiles of the active simulation (perpendicular to the electrode).
 ➢Grid Points (Y)Shows the number of grid points used for simulating the concentration profiles of the active simulation (parallel to the electrode).
 Info: Flux Error➢Relative Flux ErrorShows an estimation of the relative flux error that might be involved in the the active simulation.
 Option: C-Profiles Display➢Use Thick Pen Controls whether a thick or the default pen is used for drawing the surface concentration (or surface coverage).
 Option: Labels➢X-AxisOption for customizing the label on the x-axis.
 ➢Y-AxisOption for customizing the label on the y-axis.
 Option: Colors➢BackgroundOption for customizing the color of the background on which the surface concentration (or surface coverage) is plotted.
 ➢LabelsOption for customizing the color with which the axes are labeled.
 ➢Species Name_1Option for customizing the color with which the surface concentration (or the surface coverage) of the first species is plotted.
 ➢Species Name_2Option for customizing the color with which the  surface concentration (or surface coverage) of the second species is plotted.
           : ➢Species Name_nOption for customizing the color with which the surface concentration (or surface coverage) of the n-th species is plotted.
 Option: Font➢Screen FontOption for customizing the font used for plotting min/max-info and for labeling the axes on the screen display.
 ➢Printer FontOption for customizing the font used for printing min/max-info and for labeling the axes.
 Option: Export Data (*.txt)➢Number FormatControls whether the surface concentration (or surface coverage)  is exported  in comma (1,234) or point (1.234) format.
 ➢SeparatorOption for selecting the separator used when exporting the surface concentration (or surface coverage).
 Option: emf-Files➢Save Black and WhiteControls whether the image of the screen display is saved as Extended Meta File in the original screen colors or in "black on white".
 
  Modified Options will be saved in the Windows Registry and restored when restarting the program.
   |